
Copper-silver ionization offers building operators a persistent approach to Legionella control—one designed to carry an active disinfectant residual throughout complex plumbing infrastructure. LiquiTech CEO Tory Schira explains how the technology works, what operating data matters, and why successful implementation requires more than installing equipment. How Copper-Silver Ionization Works Copper and silver ions are introduced through a flow chamber containing sacrificial electrodes. A controlled electrical charge releases the positively charged ions into the water, allowing them to travel through the plumbing system and reach areas where biofilm and Legionella may grow. Tory describes the ions as independently biocidal but more effective when working together. Copper weakens the bacterial cell wall, while silver gains greater access to the cell and disrupts the bacteria. Unlike traditional oxidants that can decay with time and temperature, copper and silver ions remain persistent across hot and cold building water systems. Designing, Monitoring, and Controlling the System Proper design begins with engineering data. The deployment team evaluates whether treatment should be installed on the hot-water recirculation loop or at the building's cold-water point of entry. Peak demand, water consumption, conductivity, and pH also influence system sizing and operation. Tory outlines target ranges of 0.1–0.8 ppm copper and approximately 30–80 ppb silver. Real-time monitoring tracks ion introduction, while samples collected from distal locations help verify distribution. Those samples are analyzed by an independent laboratory using ICP-MS testing under EPA Method 200.8. Water Management Plans Must Match the Control Method Changing a building's disinfection method should trigger a review of its water management plan. Tory cautions that many plans remain too generic and fail to define method-specific target ranges, corrective actions, and root-cause analysis procedures. The conversation also examines lessons from pandemic-era building stagnation. LiquiTech used connected-system data to identify low-flow areas and guide more targeted flushing, demonstrating how water-use visibility can strengthen operational decisions. Persistent Legionella positivity should not automatically be accepted as control. Water professionals must define success clearly, verify distribution, and align technology, monitoring, and corrective actions with the desired water-safety outcome. Listen to the full conversation above. Explore related episodes below. Stay engaged, keep learning, and continue scaling up your knowledge! Timestamps 02:30 — Trace Blackmore opens the second week of Legionella Awareness Month and explains why copper-silver ionization must operate within a broader water management plan. 04:20 — Trace highlights the Legionella Resources page, including materials from the CDC, World Health Organization, and previous podcast guests. 07:30 — Trace explains how episode discussion guides help teams turn podcast insights into practical workplace conversations and action items.<span data-ccp-props= "{"134233117":false,"13423311
Podzilla Summary coming soon
Sign up to get notified when the full AI-powered summary is ready.
Free forever for up to 3 podcasts. No credit card required.

495 Growing Through Change in Water Treatment with Mark Lewis, Part 1

494 Preparing for AWT 2026: Leadership, Change, and CWT Growth with Matt Coffindaffer, Part 2

493 Preparing for AWT 2026: Leadership, Change, and CWT Growth with Matt Coffindaffer, Part 1

492 AI for Water Treaters: A Thought Partner, Not a Replacement
Free AI-powered recaps of Scaling UP! H2O and your other favorite podcasts, delivered to your inbox.
Free forever for up to 3 podcasts. No credit card required.